Each Unit Size (W*D*H)(mm)
-
AC InputAC 380V ±10% / 50Hz
-
Input Active Power22857W
-
ResolutionAD:16bit;DA:16bit
-
Input Impedance≥100kΩ
-
Voltage
Constant Voltage Range Control: 0.25V~5V;
Minimum Discharge Voltage: 0V;
Accuracy: ± 0.05% of FS;
Stability: ± 0.05% of FS;
-
Current
Output Range per Channel: 0.5A~100A;
Accuracy: ± 0.05% of FS;
Constant Voltage Cut-off Current: 0.2A;
Stability: ± 0.05% of FS;
-
Power
Single Channel Maximum Output Power: 500W;
Stability: ± 0.1% of FS;
-
Data Acquisition
Data Acquisition Conditions
Minimum Time Interval: 1s;
Minimum Voltage Interval: 10mV;
Minimum Current Interval: 200mA;
Data Acquisition Frequency
1Hz;
-
Time
Current Response Time (10%FS~90%FS)
Maximum current rise time: 20ms;
Step Time Range
① ≤(365*24) h/step; ②Time Format Support 00:00:00:00(h, min, s, ms)
-
Charge
Charging Mode: Constant Current Charging, Constant Voltage Charging, Constant Current/ Constant Voltage Charging, Constant Power Charging;
Cut-off Conditions: Main Channel (Voltage, Current, Relative Time, Capacity, -△V);
-
Discharge
Discharge Mode: Constant Current Discharge, Constant Voltage Discharge, Constant Power Discharge and Constant Resistance Discharge;
Cut-off Conditions: Main Channel (Voltage, Current, Relative Time, Capacity);
-
Energy Efficiency
>65%
-
Cycle Life
Cycle Test Range: 1~65535次;
Single Cycle Steps: 254;
Loop nesting: it has the function of nested loop and supports up to 3 levels of nesting;
-
Protect
Power down data protection;
Function of prevention of feedback;
The safety protection conditions can be set, and the setting specs include: voltage upper limit, voltage lower limit, current upper limit, current lower limit and delay time;
Function of offline test.
-
IP Protection DegreeProtection Degree: IP20
-
Channel CharacteristicsConstant current and constant voltage adopt double closed loop structure.
-
Channel Control ModeIndependent Control
-
Voltage and Current SamplingFour Wire Connection
-
Noise<85dB
-
DatabaseAdopting MySQL database to centralized manage testing data.
-
Communication Mode of Upper ComputerBased on TCP/ IP Protocol
-
Server Operating SystemWindows 7
-
Data Output Mode
EXCEL 2003, 2010;
TXT.
-
Server Disk Configuration500GB
-
Communication InterfaceNetwork Interface
-
Total Number of Channels32
-
Working Temperature Range0℃~40℃(Within the range of 25±10℃, accuracy drift is 0.005% of FS /℃)
-
Storage Temperature Range-10℃~50℃
-
Relative Humidity Range of Working Environment≤70% RH(There is no condensation of moisture.)
-
Relative Humidity Range of Storage Environment≤80% RH(There is no condensation of moisture.)
-
Auxiliary Channel (Optional)
Type of Auxiliary Channel: Temperature and Voltage;
Temperature Range: -25℃~110℃ (Thermocouple);
Temperature Accuracy: ± 1 ℃;
Temperature Resolution: 0.1 ℃;
Voltage Range: 0V ~ 5V;
Voltage Accuracy: ± 0.1% of FS;
-
Number of Temperature Auxiliary Channels per Channel (Optional)Up to 248 Temperature Auxiliary Channels.
-
Number of Auxiliary Channels with Voltage per Channel (Optional)Up to 248 Voltage Auxiliary Channels
-
Auxiliary Channel Protection Conditions
Auxiliary Channel Protection Conditions can be Set, and the settable Specs include: Temperature Upper Limit, Temperature Lower Limit, Voltage Upper Limit, Voltage Lower Limit and Cell Differential Pressure.