Coin Cell Battery Testing System
CT-4008Tn-5V10/20/50mA-164
● Current&Voltage: 5V10mA/20mA/50mA;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz/100Hz;
● 3 Range;
● dQ/dV;
● Application: For Coin Cell
CT-4000Q-100mA-124
● Current&Voltage: 5V100mA;
● Accuracy: 0.01%FS;
● Data Acquisition Frequency: 10Hz/100Hz;
● 4 Range;
● dQ/dV;
● Application: For Coin Cell
CT-4008Tn-5V10mA(Supercap)
● Current&Voltage: 5V10mA;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency: 10Hz/100Hz;
● 3 Range;
● dQ/dV;
● Application: Supercap Testing
3C Digital Battery Testing System
CT-4008Tn-5V6A (Supercap)
● Current&Voltage: 5V6A;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz/100Hz;
● 3 Range;
● Application: Supercap Testing
CT-4008Q-5V6A-164/S1 (4 Ranges)
● Current&Voltage: 5V6A;
● Accuracy: 0.01%FS;
● Data Acquisition Frequency :10Hz/100Hz;
● 4 Range;
● Application: 3C Digital Cell Testing
CT-4008Tn-5V6A-164/S1 (3 Ranges)
● Current&Voltage: 5V6A;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz/100Hz;
● 3 Range;
● Application: 3C Digital Cell Testing
CT-4008Tn-5V12A (Supercap)
● Current&Voltage: 5V12A;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz/100Hz;
● 3 Range;
● Application: Supercap Testing
CT-4008Q-5V12A-164/S1 (4 Ranges)
● Current&Voltage: 5V12A;
● Accuracy: 0.01%FS;
● Data Acquisition Frequency :10Hz/100Hz;
● 4 Range;
● Application: 3C Digital Testing
CT-4008Tn-5V12A-164/S1 (3 Ranges)
● Current&Voltage: 5V12A;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz/100Hz;
● 3 Range;
● Application:3C Digital Testing
Intelligent laptop cell Testers
CE-5008-10V20A-SMB
● Current&Voltage: 10V20A;
● Accuracy: 0.02%FS;
● Data Acquisition Frequency: 100Hz;
● Response Time: ≤10ms;
● Others: SMBus/DBC Import/I2C Communication/Regenerative
CE-5008-20V10A-SMB
● Current&Voltage: 20V10A;
● Accuracy: 0.02%FS;
● Data Acquisition Frequency: 100Hz;
● Response Time: ≤10ms;
● Others: SMBus/DBC Import/I2C Communication/Regenerative
CE-5008-20V30A-SMB
● Current&Voltage: 20V30A;
● Accuracy: 0.02%FS;
● Data Acquisition Frequency: 100Hz;
● Response Time: ≤10ms;
● Others: 2-6 String Battery Pack Testing/3C Digital Testing (Tablet/Phone/UAV, etc.)
CE-5008-24V10A-SMB
● Current&Voltage: 24V10A;
● Accuracy: 0.02%FS;
● Data Acquisition Frequency: 100Hz;
● Response Time: ≤10ms;
● Others: SMBus/DBC Import/I2C Communication/Regenerative
CE-5008-24V15A-SMB
● Current&Voltage: 24V15A;
● Accuracy: 0.02%FS;
● Data Acquisition Frequency: 100Hz;
● Response Time: ≤10ms;
● Others: SMBus/DBC Import/I2C Communication/Regenerative
Battery Testing System for Power Cell
CTE-4008D-5V30A-(NTA)
● Current&Voltage: 5V30A;
● Total Number of Channels: 8;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CTE-4032D-5V30A
● Current&Voltage: 5V30A;
● Total Number of Channels: 32;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CTE-4064D-5V30A
● Current&Voltage: 5V30A;
● Total Number of Channels: 64;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CT-4008-5V30A-(NTA)
● Current&Voltage: 5V30A;
● Total Number of Channels: 8;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Power Cell Testing
CT-4008-5V60A-NTA
● Current&Voltage: 5V60A;
● Total Number of Channels: 8;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CTE-4032-5V60A
● Current&Voltage: 5V60A;
● Total Number of Channels: 32;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CTE-4048D-5V60A-HC
● Current&Voltage: 5V60A;
● Total Number of Channels: 48;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CT-4008-5V100A-NTA
● Current&Voltage: 5V100A;
● Total Number of Channels: 8;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CTE-4032-5V100A-NTA
● Current&Voltage: 5V100A;
● Total Number of Channels: 32;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CTE-4048-5V100A
● Current&Voltage: 5V100A;
● Total Number of Channels: 48;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CTE-4048-5V120A
● Current&Voltage: 5V120A;
● Total Number of Channels: 8;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CTE-4032-5V120A-NTA
● Current&Voltage: 5V120A;
● Total Number of Channels: 32;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CT-4008-5V120A-NTA
● Current&Voltage: 5V120A;
● Total Number of Channels: 8;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CTE-4016-5V200A
● Current&Voltage: 5V200A;
● Total Number of Channels: 16;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CTE-4004-5V500A
● Current&Voltage: 5V500A;
● Total Number of Channels: 4;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CE-6008n-5V300A-H
● Current&Voltage: 5V300A;
● Total Number of Channels: 4;
● Accuracy: 0.02%/0.05%FS;
● Data Acquisition Frequency: 100Hz;
● Response Time: ≤3ms;
● Application: Regenerative Power Cell Testing
CE-6016n-6V300A
● Current&Voltage: 6V300A;
● Total Number of Channels: 16;
● Accuracy: 0.02%/0.05%FS;
● Data Acquisition Frequency: 100Hz;
● Response Time: ≤3ms;
● Application: Regenerative Power Cell Testing
CTE-8008-5V200A
● Current&Voltage: 5V200A;
● Total Number of Channels: 8;
● Accuracy: 0.05%FS;
● Min. Pulse Width: 500ms;
● Others: Simulation/Pulse Test/Capacity Test/Cycle Life/HPPC
CTE-8008-5V300A
● Current&Voltage: 5V300A;
● Total Number of Channels: 8;
● Accuracy: 0.05%FS;
● Min. Pulse Width: 500ms;
● Others: Simulation/Pulse Test/Capacity Test/Cycle Life/HPPC
CTE-8008-5V500A
● Current&Voltage: 5V500A;
● Total Number of Channels: 8;
● Accuracy: 0.05%FS;
● Min. Pulse Width: 500ms;
● Others: Simulation/Pulse Test/Capacity Test/Cycle Life/HPPC
Battery Testing System for Module
CE-6012n-60V50A
● Current&Voltage: 60V50A;
● Total Number of Channels: 12;
● Accuracy: 0.02%/0.05%FS;
● Data Acquisition Frequency :100Hz;
● Response Time: ≤3ms;
● Application: Regenerative Power Cell Testing
CE-6008n-20V150A
● Current&Voltage: 20V150A;
● Total Number of Channels: 8;
● Accuracy: 0.02%/0.05%FS;
● Data Acquisition Frequency :100Hz;
● Response Time: ≤3ms;
● Application: Regenerative Power Cell Testing
CE-6008n-100V100A
● Current&Voltage: 100V100A;
● Total Number of Channels: 8;
● Accuracy: 0.02%/0.05%FS;
● Data Acquisition Frequency :100Hz;
● Response Time: ≤3ms;
● Application: Regenerative Power Cell Testing
Battery Testing System for PACK
CE_6002n_750V200A_IG
● Current&Voltage: 750V200A;
● Total Number of Channels: 12;
● Accuracy: 0.02%/0.05%FS;
● Data Acquisition Frequency :100Hz;
● Response Time: ≤3ms;
● Application: Regenerative Power Cell Testing