For Coin Cell | 5V10mA | 5V20mA | 5V50mA | 5V100mA | ||
For 3C Digital | 5V1A | 5V6A | 5V12A | 5V15A | 5V20A | 5V30A |
Customized | 5V~30V; | 30A~1000A; |
Coin Cell Battery Testing System
CT-4008Tn-5V10/20/50mA-164
● Current&Voltage: 5V10mA/20mA/50mA;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz/100Hz;
● 3 Range;
● dQ/dV;
● Application: For Coin Cell
CT-4000Q-100mA-124
● Current&Voltage: 5V100mA;
● Accuracy: 0.01%FS;
● Data Acquisition Frequency: 10Hz/100Hz;
● 4 Range;
● dQ/dV;
● Application: For Coin Cell
CT-4008Tn-5V10mA(Supercap)
● Current&Voltage: 5V10mA;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency: 10Hz/100Hz;
● 3 Range;
● dQ/dV;
● Application: Supercap Testing
3C Digital Battery Testing System
CT-4008Tn-5V6A (Supercap)
● Current&Voltage: 5V6A;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz/100Hz;
● 3 Range;
● Application: Supercap Testing
CT-4008Q-5V6A-164/S1 (4 Ranges)
● Current&Voltage: 5V6A;
● Accuracy: 0.01%FS;
● Data Acquisition Frequency :10Hz/100Hz;
● 4 Range;
● Application: 3C Digital Cell Testing
CT-4008Tn-5V6A-164/S1 (3 Ranges)
● Current&Voltage: 5V6A;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz/100Hz;
● 3 Range;
● Application: 3C Digital Cell Testing
CT-4008Tn-5V12A (Supercap)
● Current&Voltage: 5V12A;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz/100Hz;
● 3 Range;
● Application: Supercap Testing
CT-4008Q-5V12A-164/S1 (4 Ranges)
● Current&Voltage: 5V12A;
● Accuracy: 0.01%FS;
● Data Acquisition Frequency :10Hz/100Hz;
● 4 Range;
● Application: 3C Digital Testing
CT-4008Tn-5V12A-164/S1 (3 Ranges)
● Current&Voltage: 5V12A;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz/100Hz;
● 3 Range;
● Application:3C Digital Testing
Battery Testing System for Power Cell
CTE-4008D-5V30A-(NTA)
● Current&Voltage: 5V30A;
● Total Number of Channels: 8;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CTE-4032D-5V30A
● Current&Voltage: 5V30A;
● Total Number of Channels: 32;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CTE-4064D-5V30A
● Current&Voltage: 5V30A;
● Total Number of Channels: 64;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CT-4008-5V30A-(NTA)
● Current&Voltage: 5V30A;
● Total Number of Channels: 8;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Power Cell Testing
CT-4008-5V60A-NTA
● Current&Voltage: 5V60A;
● Total Number of Channels: 8;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CTE-4032-5V60A
● Current&Voltage: 5V60A;
● Total Number of Channels: 32;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CTE-4048D-5V60A-HC
● Current&Voltage: 5V60A;
● Total Number of Channels: 48;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CT-4008-5V100A-NTA
● Current&Voltage: 5V100A;
● Total Number of Channels: 8;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CTE-4032-5V100A-NTA
● Current&Voltage: 5V100A;
● Total Number of Channels: 32;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CTE-4048-5V100A
● Current&Voltage: 5V100A;
● Total Number of Channels: 48;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CTE-4048-5V120A
● Current&Voltage: 5V120A;
● Total Number of Channels: 8;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CTE-4032-5V120A-NTA
● Current&Voltage: 5V120A;
● Total Number of Channels: 32;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CT-4008-5V120A-NTA
● Current&Voltage: 5V120A;
● Total Number of Channels: 8;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CTE-4016-5V200A
● Current&Voltage: 5V200A;
● Total Number of Channels: 16;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CTE-4004-5V500A
● Current&Voltage: 5V500A;
● Total Number of Channels: 4;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing