Chat or Call
Mint Wu
Sales Manager - Mint Wu skypelive:.cid.d7553a84e2f43ba0
  • Phone
    Phone
    0013235717558
    Call me
  • WeChat
    Scan QR code and add WeChat
    Mint_Wu-Neware
    WeChat
  • WhatsApp
    Scan QR code and add WhatsApp
    +86-15196333435
    WhatsApp
  • E-mail
    E-mail
    mint.wu@neware.com.cn
    Send Email
Damon Yao
Sales Manager - Damon Yao skypelive:damonyao_2
  • Phone
    Phone
    +86-13924617429
    Call me
  • WeChat
    Scan QR code and add WeChat
    +86-13924617429
    WeChat
  • WhatsApp
    Scan QR code and add WhatsApp
    +86-13924617429
    WhatsApp
  • E-mail
    E-mail
    yaoyihan@neware.com.cn
    Send Email
icon
Mint Wu
Sales Manager - Mint Wu skypelive:.cid.d7553a84e2f43ba0
  • Phone
    Phone
    0013235717558
    Call me
  • WeChat
    Scan QR code and add WeChat
    Mint_Wu-Neware
    WeChat
  • whatapp
    Scan QR code and add WhatsApp
    +86-15196333435
    WhatsApp
  • E-mail
    E-mail
    mint.wu@neware.com.cn
    Send Email
Damon Yao
Sales Manager - Damon Yao skypelive:damonyao_2
  • Phone
    Phone
    +86-13924617429
    Call me
  • WeChat
    Scan QR code and add WeChat
    +86-13924617429
    WeChat
  • whatapp
    Scan QR code and add WhatsApp
    +86-13924617429
    WhatsApp
  • E-mail
    E-mail
    yaoyihan@neware.com.cn
    Send Email
Damon Yao
Sales Manager - Damon Yao skypelive:damonyao_2
  • Phone
    Phone
    +86-13924617429
    Call me
  • WeChat
    Scan QR code and add WeChat
    +86-13924617429
    WeChat
  • WhatsApp
    Scan QR code and add WhatsApp
    +86-13924617429
    WhatsApp
  • E-mail
    E-mail
    yaoyihan@neware.com.cn
    Send Email
icon
Select location or language
icon
Power Cell Testing
CT-4008-5V100A-NTA
  • Each Unit Size (W*D*H)(mm)
  • AC Input
    AC 380V ±10% / 50Hz
  • Input Active Power
    7089W
  • Resolution
    AD:16bit;DA:16bit
  • Input Impedance
    ≥1MΩ
  • Voltage

    Constant Voltage Range Control: 0.025V~5V;

    Minimum Discharge Voltage: 2.5V;

    Accuracy: ± 0.1% of FS;

    Stability: ± 0.1% of FS;

  • Current

    Output Range per Channel: 0.5A~100A;

    Accuracy: ± 0.1% of FS;

    Constant Voltage Cut-off Current: 0.2A;

    Stability: ± 0.1% of FS;

  • Power

    Single Channel Maximum Output Power: 500W;

    Stability: ± 0.2% of FS;

  • Time

    Current Response Time (10%FS~90%FS)

    Maximum current rise time: 20ms;


    Step Time Range

    ① ≤(365*24) h/step; ②Time Format Support  00:00:00:00(h, min, s, ms)

  • Data Acquisition

    Data Acquisition Conditions

    Minimum Time Interval: 100ms;

    Minimum Voltage Interval: 10mV;

    Minimum Current Interval: 120mA;


    Data Acquisition Frequency

    10Hz;

  • Charge

    Charging Mode: Constant Current Charging, Constant Voltage Charging, Constant Current/ Constant Voltage Charging, Constant Power Charging;

    Cut-off Conditions: Voltage, Current, Relative Time, Capacity, -△V;


  • Discharge

    Discharge Mode: Constant Current Discharge, Constant Voltage Discharge, Constant Power Discharge and Constant Resistance Discharge;

    Cut-off Conditions: Voltage, Current, Relative Time, Capacity;

  • Pulse Mode

    Charging: Constant Current Mode and Constant Power Mode;

    Discharge: Constant Current Mode and Constant Power Mode;

    Minimum Pulse Width: 500ms;

    Number of Pulses: A Single Pulse Step Supports 32 Different Pulses;

    Continuous Switching of Charge and Discharge: One Pulse Step can Realize Continuous Switching from Charge to Discharge;

    Cut off Conditions: Voltage, Relative Time;

  • Cycle Life

    Cycle Test Range: 1~65535 times;

    Number of Single Cycle Steps: 254;

    Loop Nesting: It has the Function of Nested Loop and Supports Up to 3 Levels of Nesting;

  • DCIR Test
    Support DCIR calculating with user defined point.
  • Protect

    Power down data protection;

    Function of prevention of feedback;

    The safety protection conditions can be set, and the setting specs include: voltage upper limit, voltage lower limit, current upper limit, current lower limit and delay time;

    Function of offline test.

  • IP Protection Degree
    Protection Degree: IP20
  • Channel Characteristics
    Constant current and constant voltage adopt double closed loop structure.
  • Channel Control Mode
    Independent Control
  • Voltage and Current Sampling
    Four Wire Connection
  • Noise
    <85dB
  • Database
    Adopting MySQL database to centralized manage testing data.
  • Server Disk Configuration
    500GB
  • Communication Mode of Upper Computer
    Based on TCP/ IP Protocol
  • Leakage Current
    0.005mA
  • Server Operating System
    Windows 7
  • Data Output Mode

    EXCEL 2003, 2010; 

    TXT.

  • Communication Interface
    Network Interface
  • Total Number of Channels
    8
  • Working Temperature Range
    0℃~40℃(Within the range of 25±10℃, accuracy drift is 0.005% of FS /℃)
  • Storage Temperature Range
    -10℃~50℃
  • Relative Humidity Range of Working Environment
    ≤70% RH(There is no condensation of moisture.)
  • Relative Humidity Range of Storage Environment
    ≤80% RH(There is no condensation of moisture.)
Neware and Cookies
This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies.Read our private policy

Neware Official Website